| 152 | 7 | 81 |
| 下载次数 | 被引频次 | 阅读次数 |
给出了单相电力有源滤波器的一种新的控制算法:负荷有功分量法.使用该算法的单相电力有源滤波器,对对称和非对称负载产生的谐波具有较好的抑制作用,在电源电压畸变的情况下,也能保证负载电源侧电流为正弦波.样机实验表明,该滤波器具有较好的滤波特性.
Abstract:A new algorithm based on calculation of the real part of the fundamental load current is proposed for a single phase active power filter.The algorithm proposed can maintain the input power factor of the mains colse to unity and force the mainscurrent to be a sinewave under distorted or nondistorted mains voltage.A prototype is developed and is tested to verify its performance.The experimental results show that the filters have good capability.
1TAKEDAM.HarmonicCurrentandReactivePowerCompensationwithanActiveFilter.IEEEPESC88Record,1988,1174~11792CHOEGH.AnalysisandControlofActivePowerFilterwithOptimizedInjection.IEEETRANS,1989,PE-4(4):427~4333王良.有源滤波器对三相不平衡负荷的谐波补偿.北方交通大学博士学位论文,19924李亚男.电压型开关逆变器电力滤波方式的仿真与分析.华北电力大学硕士学位论文,1994
基本信息:
中图分类号:TP391.9,TN713.8
引用信息:
[1]任万强,张一工,张金元.单相电力有源滤波器的仿真与研究[J].郑州大学学报(自然科学版),1998(03).